DeWalt Powers Adhesive AC200 Plus
The AC200+ is a two-component, high strength adhesive anchoring system. The system includes injection adhesive in plastic cartridges, mixing nozzles, dispensing tools and hole cleaning equipment. AC200+ is designed for bonding threaded rod and reinforcing bar hardware into drilled holes in concrete base materials and for post-installed reinforcing bar connections (rebar development).
Features:
- Fast curing system which can be applied in structural applications as low as 14°F (-10°C)
- Evaluated and recognized for freeze/thaw performance and sustained loading
- Can be used in a wide range of embedments in low and high strength concrete
- Cartridge design allows for multiple uses using extra mixing nozzles
- Mixing nozzles proportion adhesive and provide simple delivery method into drilled holes
- Evaluated and recognized for long term and short term loading (see performance tables)
- In-service temperature ratings between -40°F (-40°C) and 320°F (160°C)
Specifications:
| Catalog Number | Description | Pack Qty |
|---|---|---|
| PFC1271050 | AC200+ 9.5 fl. oz. Quik-Shot | 12 |
| PFC1271110 | AC200+ 14 fl. oz. Coaxial cartridge | 12 |
| PFC1271150 | AC200+ 28 fl. oz. Dual cartridge | 8 |
Applications:
- High strength anchoring: bonding threaded rod and reinforcing bar into hardened concrete
- Rebar development length and lap splice connections in concrete up to 60d embedments
- Evaluated for installation and use in dry and wet concrete (including water-filled holes)
- Cracked and uncracked concrete conditions as well as wind and seismic loading (SDC A – F)
- Oversized hammer-drilled holes in concrete, for short term loading only (see www.DEWALT.com)
- Can also be considered for filling large cracks and abandoned holes in concrete and masonry
Approvals & Listings
- International Code Council, Evaluation Service (ICC-ES) ESR-4027 for cracked and uncracked concrete
- Code Compliant with the International Building Code/International Residential Code: 2021 IBC/IRC, 2018 IBC/IRC, 2015 IBC/IRC, and 2012 IBC/IRC
- Tested in accordance with ACI 355.4, ASTM E488, and ICC-ES AC308 for use in structural concrete with design according to ACI 318 (-19 & -14), Chapter 17 and ACI 318-11 Appendix D
- Evaluated and qualified by an accredited independent testing laboratory for recognition in cracked and uncracked concrete including static, wind and seismic loading
- Tested and qualified for use in post-installed rebar connections including rebar development and lap splices in accordance with ICC-ES AC308 Table 3.8 and ACI 318 Chapter 12 and Chapter 25
- City of Los Angeles, LABC and LARC Supplement (within ESR-4027)
- Florida Building Code, FBC Supplement including HVHZ (within ESR-4027)
- European Technical Approval, ETA-16/0905 (adhesive anchors), ETA-16/0904 (post-installed rebars)
- Compliant with NSF/ANSI 61 for drinking water system components – health effects
- Compliant to California DPH for VOC emissions and South Coast AQMD for VOC content (LEED v4.1)
- Conforms to requirements of ASTM C881 including C882 and AASHTO M235, Types I, II, IV and V, Grade 3, Class A and conforms to requirements of ASTM C881 Types I and IV, Grade 3, Class B
- Department of Transportation listings – see www.DEWALT.com or contact transportation agency